Display the Waterfall Plot

When you are finished setting up the plot parameters, you can process the
spectral data by pressing F3 (Display) on the RUCD - Waterfall Setup screen.

Optimize the Waterfall Plot

Additional parameters display on the screen letting you to control how the
spectra appear in the waterfall plot.

1.

Select the option and press the Right arrow to open a list of values.

2.

Select or type in a parameter value.

3.

Press the Left arrow to save your selection.

Use the descriptions in

Waterfall Plot Setup Parameters on page 34

to help

you configure the parameters.

LF Cutoff (EU)

Sets a low frequency cutoff filter to remove noise from the analysis.

The available options are determined by the X-axis selection.

Off

21.6 CPM

66 CPM

120 CPM

600 CPM

4200 CPM

.36 Hz

1.1 Hz

2 Hz

10 Hz

70 Hz

Table 7 - Waterfall Plot Parameters

Parameter Name

Description

Values/Comments

TIP

The larger the .wav file, the longer it takes to process the data
and display the plot.