Accessing the configuration mode, Disabling a process display variable – Rockwell Automation 1201 GRAPHIC PROGRAM TERM 3.XX User Manual

Page 49

Advertising
background image

Chapter 7
Process Display

7–4

From any Process Display window press the

F1

soft key to

call up the Configuration display (Figure 7.5).

Figure 7.5

Configuration Display

0.00 FREQ CMD

0.00 VEL FB

0.00 COMP PWR

0.00 MTR V FB

0.00 MTR I FB

0.00 TORQ FB

Data

Parameter: 266

Scale: +1.0

Text: FREQ CMD

Program

Disable

Recall

Init_ALL

<

>

To disable a process display variable use the

or

key

to place the cursors on the variable you wish to Disable. Press the

F2

soft designator. The data display window will change to

display “None” in the parameter line (Figure 7.6).

Figure 7.6

Disable Parameter Configuration Display

0

0.00 VEL FB

0.00 COMP PWR

0.00 MTR V FB

0.20 MTR I FB

0.00 TORQ FB

Program

Disable

Recall

Init_ALL

Data

Parameter: None

Scale: +1.00

Text:

<

>

If you wish to re-enable the parameter that was just removed press the

F2

soft designator key again. The

F2

soft designator has now changed to an Enable variable.

Accessing the Configuration Mode

Disabling a Process Display

Variable

Advertising