Balancing Extension Module Chapter 2

If the Trial Run magnitude is over 200% of the Initial Run magnitude, this

warning appears:

3.

In either case, press F2 (Yes) to return to the Add Trial Weight – Plane 1
screen where you can adjust your settings or press F3 (No) to continue with
the current settings.

With the 30/30 rule satisfied, the data collector uses differences between
the reference run readings and trial run readings to compute the influence
coefficient, which it uses to compute the permanent correction weight
solution.

4.

If you need to, correct any values.

5.

From the Trial Weight Measurement screen, press Enter to proceed.

Before computing the correction weight solution, you are prompted to
indicate whether the trial weight is to remain attached or be removed.

Trial weights are normally temporary, and removed before one final
correction weight is attached. However, sometimes the trial weight must
be permanently attached for safety purposes, and is therefore left on the
machine.

6.

Select No, as you typically plan to remove the temporary trial weight (or
select Yes if you plan to leave the trial weight attached).