Rockwell Automation 1441-DYN25-MBAL Balancing Extension Module for the Dynamix 2500 User Manual

Page 54

Advertising
background image

54

Rockwell Automation Publication 1441-UM004A-EN-P - May 2011

Chapter 2 Balancing Extension Module

The Add Trial Weight – Plane 2 screen appears.

For more information, see

Add the Trial Weight on page 28

.

7.

Attach the Trial Weight to Plane 2.

8.

Stop the machine.

9.

On the data collector, enter the Mass, Angle and Radius for the trial weight
you are attaching to Plane 2 (typically the same weight used on Plane 1).

A negative number can be entered if trial weight is removed, instead of
added. Trial weights are typically attached at 0°.

10.

On Plane 2, carefully attach the precise weight at the precise angle and
radius specified.

Balancing results depend greatly on the precision of your measurements
and actions.

Perform Trial Run 2 on Both Planes

1.

With the trial weight securely attached to the Plane 2, start the machine
and bring it back up to the same speed used with the reference runs (initial
runs).

2.

Press Enter.

You are prompted to verify the transducer is attached to the bearing closest
to Plane 1.

3.

Verify your transducer is attached and press the Yes function button.

The Trial Run 2 – Plane 1 screen displays. The Trial Run 2 – Plane 2 screen
shows vibration magnitude and phase readings for Plane 2 with the trial
weight on Plane 2.

Advertising