35

Balancing Extension Module Chapter 2

Take a Correction Run

The Correction Run screen displays, showing the amount of residual unbalance
with the correction weight attached.

Verify whether the amount of residual unbalance is within specifications for the
machine. If the amount of residual imbalance is within specifications, you can end
the balance measurement, if not, you should proceed with a trim run.

1.

Press Enter.

You are prompted whether you wish to perform7 a trim run.

The data collector automatically measures the speed, vibration, and phase.
The values are constantly updated on the screen.

2.

If necessary, press Yes to proceed with a trim run.

If the vibration magnitude is
greater than this threshold, the
magnitude bar is colored red
when taking a reading. The bar
turns green when the selected
level of imbalance is achieved.