Rockwell Automation 1441-DYN25-MBAL Balancing Extension Module for the Dynamix 2500 User Manual

Page 55

Advertising
background image

Rockwell Automation Publication 1441-UM004A-EN-P - May 2011

55

Balancing Extension Module Chapter 2

4.

Press Enter to proceed.

Before computing the correction weight solution, you are prompted
whether the trial weight is to remain attached to Plane 1.

5.

Select No, as you typically plan to remove the temporary trial weight (or
select Yes if you plan to leave the trial weight attached).

The Correction Weight - Solution screen displays for Plane 1 of 2.

6.

Add the Correction Weights.

The Correction Weight - Solution Screens for both Planes.

The Correction Weight – Solution screen displays fields at the top of the
screen, and the permanent correction weight mass, angle, and radius
balance solution for the two planes at the bottom of the screen.

7.

Use the Plane field to view each Plane’s correction weight data.

8.

Stop the machine, remove the temporary trial weight from Plane 2, and
securely attach the permanent correction weights on Planes 1 and 2 (at the
precise angles and radii specified).

Perform Correction Weight Runs on Both Planes

1.

Start the machine.

2.

With your permanent correction weights in place on both planes, from the
Correction Weight – Solution screen, press Enter to begin the correction
runs.

You are prompted to verify the transducer is attached to the bearing closest
to balancing Plane 1.

3.

Verify the transducer and press Yes.

Advertising