Attach the Trim Weights.

The Trim 1 Weight – Solution screen appears showing the trim weight
mass, angle, and radius for both planes.

12.

Use the Plane field to view each Plane’s trim weight data.

13.

Write each field’s trim weight data on a piece of paper before proceeding.

14.

Stop the machine, and securely attach the trim weights on Planes 1 and 2
(at the precise angles and radii specified).

Perform Trim Runs on both Planes

1.

Start the machine.

2.

With your trim weights attached on both planes, from the Trim Weight –
Solution screen, press Enter to begin the trim runs.

You are prompted to verify the transducer is attached to the bearing closest
to balancing Plane 1.

3.

Verify the transducer and press Yes.

The Trim Run – Plane 1 screen appears showing the amount of residual
unbalance on Plane 1 with the trim weights attached.

If two transducers are used for the balancing, both planes appear
simultaneously.

4.

Verify whether the amount of residual unbalance is within specifications.

5.

From the Trim Run – Plane 1 screen, press Enter.

You are prompted to verify the transducer is attached to the bearing
nearest Plane 2.