The Correction Weight – Solution screen displays.

7.

From the Correction Weight Solution screen, press Enter to begin the
correction run.

The Correction Weight – Solution screen displays fields at the top of the
screen, and the permanent correction weight mass, angle, and radius
balance solution for the field settings.

8.

Stop the machine, remove the temporary trial weight, and securely attach
the permanent correction weight at the precise angle and radius specified.

Parameter

Description

Split Mass?

Sometimes a weight cannot be placed at the angle specified by balancing
computations. The Split Mass? option automatically splits the specified
weight into two weights positioned at two placement angles around the
original angle.

Weight Add/Subtract Specifies whether you are adding or subtracting the correction weight.

Mass and Angle settings automatically adjust per your selection. Defaults
to Add.

Radius

Lets you to specify a new weight placement radius. Mass and Angle
settings automatically adjust for the new radius. If you split weights, a
radius setting is available for each weight.

Angle (1) / Angle (2)

Applicable only if you split weights. Lets you to specify the placement angle
for the two weights. Both angles must be specified for weight recalculation.
The data collector recalculates the weight for each position based on the
relative phase between the correction weight and the split weight locations.