Supported Block Transfer Messages

Product ID Number Read

Product ID Number Read returns the product ID of the device to
which the Remote I/O module is connected.

PLC Block Transfer Instruction Data

PLC request instruction length: 3 words
Drive response instruction length: 4 words

Figure B.6

Message Structure

Message Operation

Product ID Number Read, through the drive response message
word 3, indicates the type of device the Remote I/O module is
connected to. This value is defined in the message response chart
shown above.

If an error has occurred, word 1 of the response returns a negative
value of –32512.

Header

Word 0

PLC Decimal Value

256

Header

Word 1

Header

Word 2

PLC Request

Header Word 0

Header Word 1

Data Word 2

Message Length

Message Length

PLC Decimal Value

256 — Message OK

–32512 — Message Error

0

Drive Response

3

0

4

Data

Word 3

Product ID Number

or Error Code

Product Code
(Hex)

Product Code
(Decimal)

Bulletin
Number

Product

0x02

2

1336S

1336 PLUS 0.5 – 10 HP

0x03

3

1336S

1336 PLUS 7.5 – 800 HP

0x07

7

1336F

1336 PLUS II

0x10

16

1336T

1336 FORCE w/PLC Adapter Board

0x11

17

2364F

2364 RGU DC Bus Regen Front End

0x12

18

1394

1394 Motion Drive

0x13

19

1557

1557 Medium Voltage AC Drive

0x14

20

193

SMP-3

0x15

21

150

SMC Dialog Plus

0x17

23

1305

1305 AC Drive

0x18

24

1397

1397 DC Drive

0x19

25

1336R

1336 Line Regeneration Package

0x20

32

1336T

1336 FORCE w/Standard Adapter Board

0x22

34

1336E

1336 IMPACT

Advertising