Setting the Node Address
If switches 7 and 8 on the DeviceNet option are On, the value of Parameter
103 - [NV MAC ID] determines the node address. By default, this
parameter sets the node address to 63. We recommend changing the node
address to a new, unique node address because all new devices use 63 as a
default node address.
1. In the Device Configuration - Enhanced Mode dialog box (
),
double-click Parameter 103 - [NV MAC ID]. The Device
Configuration - Modify Numeric Parameter dialog box appears.
Figure 3.9 Modifying the Node Address Parameter
2. Type a unique node address, and then click Save to Device.