Rockwell Automation 1746-BAS-T SLC 500 Basic Basic-T Modules User Manual

Page 21

Advertising
background image

Publication 1746-UM004B-EN-P - December 2005

Module and Development Software Overview 1-9

Figure 1.5 BASIC Development Software Interface (RS-232)

In this configuration, the serial port on the personal computer is
connected to port PRT1 on the module. The personal computer
communicates with the module through terminal emulation over an
RS-232 interface. Port PRT1 must be configured as the program port.

See Chapter 3 for additional information on port configuration.

BASIC Development Software Interface (DH485)

In this configuration, the serial port on the personal computer
interfaced with port DH485 on the module through a 1747-PIC
interface/converter. Port DH485 must be configured as the program
port with DH485 protocol.

See Chapter 3 for additional information on port configuration.

Figure 1.6 BASIC Development software Interface (DH485)

Personal Computer with BASIC

Development Software

Null Modem

Cable

SLC 500 Controller with BASIC or BASIC-T Module

IMPORTANT

When using the BASIC development software to
interface with the RS-232 port of the module, PBASE
must be configured for RS-232 communication
through the configuration and terminal selection
menus. Refer to the BASIC Development Software
Programming Manual, publication 1746-PM001, for
additional information.

ASCII Terminal or Personal

Computer Running ASCII

Terminal Emulation Software

Interface/Converter

RS-232 to RS-485

Catalog Number 1747-PIC

SLC 500 Controller
with BASIC or
BASIC-T Module