Programming Overview 4-11

Stop a BASIC Program

To stop a program that is running, press

[Ctrl–C]

.

Edit a BASIC Program Line Through an ASCII Terminal

When the module is in Command mode, you can edit the BASIC
program that resides in RAM. Editing a BASIC program is done on a
line-by-line basis. To edit an existing line in the BASIC program, type

EDIT

and the line number of the line to edit as shown on the following

screen:

The BASIC program line specified by the Edit command is displayed
on the ASCII terminal. You can perform any of the following edit
operations.

• Cursor right and left
• Replace a character
• Insert a character
• Delete a character
• Retype a line

The table on the next page lists the BASIC edit operations, their
functions, and keystrokes required to perform the edit operation.

IMPORTANT

If

[Ctrl–C]

is disabled, you cannot stop program

execution through a BASIC command. You must
have jumper JW4 set in the default position and cycle
power to stop program execution.

READY

>EDIT 10