Configure the i/o modules – Rockwell Automation 1734-AENT, Series B POINT I/O EtherNet/IP Adapter Module User Manual User Manual

Page 42

Advertising
background image

32

Rockwell Automation Publication 1734-UM018B-EN-P - October 2013

Chapter 4 Configure the Adapter for Direct Connection in RSLogix 5000 Software

5. Select the correct Version, Chassis Type, and Slot number of the L63

controller, and the folder where you want to save the RSLogix 5000 file
(Create In). The Description is optional.

6. Click OK.

Configure the I/O Modules

You now add the POINT I/O modules to the controller’s I/O configuration
performing these procedures:

Add the local 1756-ENBT Bridge module to the I/O configuration.

Add the 1734-AENT/B adapter as a child of the 1756-ENBT module on
the Ethernet network.

Add the POINT I/O modules as children of the AENT/B adapter.

Add the Local EtherNet/IP Bridge to the I/O Configuration

1. Right-click the I/O Configuration folder in the project dialog, and select

New Module.

IMPORTANT

Click the Help button on the configuration dialogs shown in this
section if you need assistance in selecting and setting the
parameters.