12Ć5

On Line Menu: Connect

12.5

Connecting to a Network or a Local Rack

You can communicate with an AutoMax rack by using either an

RSĆ232 serial connection to a Processor in the rack or by using a PC

Link module (M/N 57C445). You can choose which one of these

methods you want to use for communication to AutoMax racks (see

section 5.5.3 for instructions).
When using a serial connection, communication between the

personal computer running the AutoMax Executive software and a

given rack in the system can take place either directly with the local

rack or over a network through the Network Communication module

(M/N 57C404A). The default status is direct communication with the

rack that is physically connected to the personal computer. See

12.5.1 and 12.5.2 for more information on direct and network

communication.
When using a PC Link module, communication can be established

with any rack on the network through the coaxial cable that is used

by the network. Direct communication with the local rack is not an

option when using the PC Link module. See 12.5.2 for more

information on network communication.
Note that you do not need to establish a network connection through

the ON LINE menu to load an operating system over a network. The

loading procedure is always performed through the Commands

menu in the System Configurator.

12.5.1

Direct Communication with the Local Rack

Selecting D" for Direct" from the ON LINE CONNECT menu will

cause the Executive software to send all communication to the rack

to which the personal computer is directly connected. The word

direct" will be visible on the top line of most ON LINE menu screens.

Direct connection is the default status.

12.5.2

Network Communication

Selecting N" for Network" from the ON LINE CONNECT menu will

cause the Executive software to send all communication to the

network rack (drop) specified. Until you change the type of

connection, either by using N" for Network" to connect to another

network rack or by using D" for Direct," all communication will take

place with the specified rack.
If you are using a PC Link module, the Executive software will display

the screen shown in figure 12.3. You can skip to the description that

follows figure 12.3.
If you are using serial communication, the Executive software will

display the screen shown in figure 12.2.