Route cables for your motion panel, Route cables for your, Motion panel – Rockwell Automation 2098 CompactLogix Indexing Motion Accelerator Toolkit Quick Start User Manual

Page 39

Advertising
background image

Publication IASIMP-QS011B-EN-P — January 2009

39

Plan System Wiring

Chapter 4

Route Cables for Your Motion Panel

The base system enclosure diagrams for the three-axis motion control panel, including noise
zones, is shown below. The enclosure CAD drawings are provided as examples of best-practices
techniques used to minimize electrical noise, as covered in the System Design for Control of
Electrical Noise Reference Manual, publication

GMC-RM001

.

The enclosure diagram provides designators that coordinate with the wiring diagrams, illustrating
where to route your power and I/O cables.

Sample Information from Enclosure Files

IMPORTANT

Refer to the Ultra3000 Digital Servo Drives Installation Manual, publication

2098-IN003

, for

installation and wiring instructions specific to the Ultra3000 drives. For other equipment shown in
your CAD drawings, refer to the installation instructions that came with those products.

LIM Module

Ultra3000 Digital
Servo Drives
(230V AC shown)

CompactLogix

Controller
(L23E shown)

Lin

e Filte

r

(op

ti

ona

l)

Ethernet Modem (optional)

PowerFlex 40

(optional)

CLEAN wireway for noise-sensitive

device circuits.

DIRTY wireway for noise-generating

device circuits.

Noise Zone Legend

Advertising
This manual is related to the following products: