Motion FactoryTalk View Integration

Chapter 6

Configure Target Communications

The Target tab displays the offline configuration from the perspective of the device that is
running the application and comprises the topology that is loaded into the PanelView Plus
terminal. In this example application, the PanelView Plus terminal communicates to the same
CompactLogix L32E controller via Ethernet.

Follow these steps to configure target communications.

1. Click the Design (Local) tab in the

Communication Setup window.

2. Click Copy from Design to Runtime.

This RSLinx Enterprise message
window opens.

3. Click Yes.

4. Click the Runtime (Target) tab and

expand the RSLinx Enterprise tree.

5. Verify that your controller and

shortcut name are both highlighted.

This indicates that communication is
established.

In this example, 1769-L32E is the
controller and CLX is the shortcut.

6. Click OK.