4-8

ADS 3600 Flow Monitor O&M Manual

9. Insert the spreader mechanism screw through the hole at the end of the right

side so that the end of the right side of the ring fits snugly against the ring
stabilizer.

Ring Stabilizer Fully Connected (Side View)

Connecting the Spreader Mechanism

Once the ring has been assembled, the spreader mechanism must be attached. The
spreader mechanism is delivered assembled and only needs to be attached to the ring.
Follow these steps in order to attach the spreader mechanism to the ring.

1. Place the ring on a flat surface with the spreader mechanism screw facing up.

2. Orient the ring so that the holes along the edge (downstream side) are facing

you.

3. Orient the spreader mechanism on the inside of the ring so that the downstream

end of the mechanism (the end with a large welded nut) is facing you, the four
spreader bars are facing towards the inside of the ring, and the shoulder bolts
are pointed towards the outside of the ring.