Monitor Installation and Activation

5-7

The following supplies are required for installing the pavement box.

Quantity

Unit

Description

1

Each

Quazite PG1730BB12 Box with Mouseholes

1

Each

Quazite PG1730CA00 Non-Locking Cover

1

Each

Quazite UH0357AA Long Cover Hook (for cover removal)

1

Each

13 mm (0.5 in.) Rigid Galvanized Conduit Nipple--a

minimum of 15 cm (6 in.) longer than the manhole wall

thickness

1

Each

Type EY-1, 13 mm (0.5 in.) Sealing Fitting--Killark (brand)

or equivalent

1

Each

Noalox Conduit Joint Compound--Ideal (brand) or

equivalent

2

Kg (5 lb)

Hydraulic cement--Thompsons (brand) or equivalent

2

Each

13 mm (0.5 in.) Plastic Bushings

1

Each

13 mm (0.5 in.) diameter by 25 mm (1 in.) long Nipples

1

Each

Roll of PVC Electrical Tape

25

Kg (50 lb)

Pea Gravel

20

L (5 gal)

Clean Water for Cement and Tool Clean-up

If installing the conduit from the manhole to the pavement box,
you will also need the following parts and supplies.

1

Each

Female 13 mm (0.5 in.) PVC Adapter

as

needed

m or ft

13 mm (0.5 in.) PVC conduit (must be long enough to

extend from the manhole to the pavement box)

7

Each

Smooth 90

°

13 mm (0.5 in.) PVC Elbows

1

Each

Can of PVC Primer (follow all of the safety instructions

on the label)

1

Each

Can of PVC Glue (follow all of the safety instructions on

the label)