Mounting the sensors, Mounting an ultrasonic sensor, Mounting a doppler velocity sensor – ADS Environmental Services Model 3600 530002 A2 User Manual

Page 46: Ring, sensor, and special installations 4-13

Advertising
background image

Ring, Sensor, and Special Installations

4-13

Mounting the Sensors

The following topics guide you through the steps necessary to mount the ultrasonic,
velocity, and pressure sensors. The following figure illustrates their positions on the
ring.

Crank

180

°

With Silt

Without Silt

Ultrasonic

Depth

Crank

Ultrasonic

Depth

Pressure

Velocity

180

°

+ ?

°

Depth

Velocity

0

°

0

°

Sensor Positions

Note:

When mounting the sensors, check on the site report to see if silt is

present. If silt is present, this will affect the sensor placement on the ring.
Refer to 4-18 for more information on silt deposits.

Mounting an Ultrasonic Sensor

Mount the ultrasonic sensor to the inside of the ring.

l

Slide the base of the sensor into the sensor mount (located at the top of the
ring). The top of the sensor (with the four disk-shaped transducers) should
face downwards towards the surface of the water.

l

Verify that the ultrasonic sensor is mounted on the ring at the pipe’s crown
(soffit). Later, when installing the ring and sensor into the pipe, you will have
to verify that the ultrasonic sensor is both horizontally and vertically level with
the surface of the flow.

Mounting a Doppler Velocity Sensor

l

Mount the velocity sensor to the inside of the ring with two M-3

×

10 mm

stainless steel screws. This sensor should be placed below and perpendicular
to the ultrasonic sensor. Do not substitute any other screws.