Ring, Sensor, and Special Installations

4-31

93038

S/C mount installed correctly
good return signal

Pooling in the invert

Velocity
sensor

Because the Bracket Mounts onto the Manhole Wall, Be Aware that Rungs and Brick Outcroppings May Affect the

Ultrasonic Sensor Readings.

93039

S/C mount installed incorrectly
signal return affected by protrusion

Pooling in the invert

Velocity
sensor

Concrete brick or
extented pipe obstructions

In Some Instances, the Pulse Command and Spare 2 Must Be Adjusted to Record the Correct Depth Readings.