Assigning Valve biCoders to Zone Numbers

You can assign any valve biCoder serial number to any zone number.

You may also wish to reassign and/or reorder certain zones in order to properly combine primary and linked zones

in a scheduling group.

The 3200 makes these assignments quick and easy to do, but be sure to document any changes that you make.

Failure to properly document assignments can cause confusion and frustration for maintenance staff.

Zone Numbers are Pre-Assigned in R-Series

When you order a conventionally wired BaseStation 3200R controller, it is pre-programmed at the factory so that

that terminal 1 is assigned to zone 1, terminal 2 is assigned to zone 2, and so on. You can change these zone

numbers to organize scheduling groups, primary, and linked zones to achieve optimal watering behavior.

Note: Baseline recommends that you use the Hydrozone Worksheet on page 88 to plan the conversion from your

existing irrigation controller to your new BaseStation 3200.

To change or re-order zone numbers in an R-series unit, perform the steps in Clearing a Previous Zone Number

Assignment on page 38, and then assign each biCoder serial number to the desired zone number. Refer to

Assigning biCoders to Zones on page 38.

Note: The serial numbers for all terminals in 3200R controllers are shown on the label next to the terminals. The

serial numbers for terminals in 5200R biCoders are shown on the door label.

Assigning biCoders to Zones

After you have wired your valve biCoders to the two-wire and the controller has detected those biCoders, you

need to assign the biCoders to the appropriate address (zone number) in the controller.

Note: If you are converting an existing irrigation controller to a new BaseStation 3200, Baseline recommends that

you use the Hydrozone Worksheet on page 88 to plan the conversion.

1. If you have not searched for the biCoders, do that first. Refer to Searching for biCoders (including Powered

biCoders) on page 36.

2. With the dial in the biCoder Menu position and the biCoder List

displayed, press the + or button to select any unassigned biCoder

serial number.

3. Press the NEXT or PREV button to select an available zone number.
4. Press the ENTR button to assign the selected biCoder to that zone

number.
Note: Use this method to assign master valves MV1-MV4. You can

assign any single or two-valve biCoder as a master valve.

5. When you have finished making changes, turn the dial to the Auto Run position.

Clearing a Previous Zone Number Assignment

You can reassign your biCoders to different zone numbers in order to accurately represent your irrigation system

and the primary zones and scheduling groups that you want to use.

1. If you have not searched for the biCoders, do that first. Refer to Searching for biCoders (including Powered

biCoders) on page 36.