BaseStation 3200 Advanced Irrigation Controller Manual

Prerequisites for Watering with Soil Moisture Sensors

• Your biSensors are installed and assigned in the BaseStation 3200. Make sure to assign the correct biSensor to

its primary zone. Making an incorrect assignment here will result in unexpected and confusing water behavior.

Refer to Assigning Soil Moisture Sensors (biSensors) to Primary Zones on page 40.

• You have created scheduling groups (a primary zone with linked zones) that combine areas with similar

watering needs (hydrozones). For example, the zones that water the softball field would be in one scheduling

group and the zones that water the north lawn between the sidewalk and the building would be in another

scheduling group. Refer to Linking Zones (Creating a Scheduling Group) on page 45.

To configure your biSensors and set up watering strategies

1. Turn the dial to the biSensor Menu position.
2. Press the NEXT button to select Configure biSensors, and then press the

ENTR button. The Configure biSensors screen displays.

3. If you have more than one biSensor installed and assigned, verify that the

correct sensor is selected. If the biSensor that you want to configure is

not displayed in the field, press the + or button to select the correct

one.

4. Press the NEXT button to move to the Water Strategy field, and then

press the + or button to select the water strategy that you want to use.
IMPORTANT NOTE! If you select any of the Upper or Lower Limit strategies, be sure to read the information

below for a complete explanation of these strategies.

5. Press the NEXT button to move to the Calibrate field.

If you selected Lower or Upper (one of the Manual strategies), you can set this field to OFF or Once (to

indicate a single calibration cycle).

If you selected Lower Auto or Upper Auto, you can set this field to Next to run a calibration cycle on the

next start time, or to Monthly after the system completes the first calibration cycle.

If you want to run an additional calibration cycle during the month, change Monthly to Next.

Note: Calibration cycles require that soak cycles be enabled. When you set these watering strategies, soak

cycles will be automatically enabled. You may change the settings to meet your specific needs, but if you

disable the soak cycles, the calibration cycle will fail.

6. Press the NEXT button to move to the Adjust field. If you selected Lower Auto or Upper Auto, you can set the

limit wetter or drier to adjust the moisture to your specific needs.

7. Press the NEXT button to move to the Manual/Auto Limit field.

If you selected Lower or Upper (one of the Manual strategies) and there is a calibration cycle scheduled,

this field displays Pending. If you set the Calibration field to OFF, you can press the NEXT button to select

the Manual Limit field and then press the + or button to change the value in the field.

If you selected Lower Auto or Upper Auto, you cannot change this field.

8. When you have finished making changes, turn the dial to the Auto Run position.

Note: If for any reason the biSensor becomes damaged or fails (12 hours of failed data or communication) the

corresponding primary zone and linked zones will water based on a timed operating mode which is based on

set water times and program schedule.