8. When the program is selected, press the + or button to change between Y (yes) and (no).

Note: If you want to turn off the pause biCoder, select the Pause Delay Time field, and then press the CLR

button.

9. When you have finished making changes, turn the dial to the Auto Run position.

Configuring Flow biCoders, Flow Meters, and Flow Sensors

Flow Meters and Flow Sensors are configured on the Flow Menu dial position. Refer to Configuring a Flow Device

on page 57 for detailed instructions for assigning and configuring Flow biCoders, Flow Meters, and/or Flow

Sensors.

Configuring a Master Valve/Pump Start biCoder

1. If you have not searched for the biCoders, do that first. Refer to Searching for biCoders (including Powered

biCoders) on page 36.

2. With the dial in the biCoder Menu position and the biCoder List

displayed, press the + or button to select the Master Valve /Pump

Start biCoder that you wish to configure.

3. Press the NEXT or PREV button to select the Master Valve Zone you

would like to configure.

4. Press the ENTR button.

Note: You can configure a single, dual, or pump start biCoder as a

master valve.

5. When you have finished making changes, turn the dial to the Auto Run position.

Associating a Master Valve/Pump Start biCoder with Programs

1. If you have not configured the biCoders with the master valves, do that first. Refer to Configuring a Master

Valve/Pump Start biCoder on page 41.

2. Turn the dial to the MV/Pump Start position.
3. Press the + or button to select the Master Valve /Pump Start that

you want to turn on when a specified program runs.

4. Press the NEXT or PREV button to move to the list of programs, and

then press the NEXT or PREV button to select the program that you

want change.

5. When the program is selected, press the + or button to change

between Y (yes) and (no).
Note: You can associate a master valve with one or all programs.

6. When you have finished making changes, turn the dial to the Auto Run position.