7 – FLOW MANAGEMENT & MONITORING

The BaseStation 3200 provides an extensive set of flow monitoring and management capabilities to help

understand how water is being used and to reduce the effects of pipeline breaks and sprinkler malfunctions. It can

monitor actual water flow rates and compare them against the expected or

design flow rates and provide alerts and perform actions when limits or

boundaries are exceeded. The system can reduce the overall completion

time of a watering cycle by running the number of zones that best use the

available water at each minute of the watering cycle.

To access the main menu for flow management, turn the dial to the Flow

Menu position.

Using a flow device to monitor water flow rates and water used is the best

way to manage this precious resource, but even without a flow device, the

BaseStation 3200 has many capabilities that can improve the efficiency of your system.

Configuring a Flow Device

1. Search for the flow device.

a. Turn the dial to the Flow Menu position.
b. Press the NEXT or PREV button to select Flow Device Setup.
c. Press the ENTR button. The Flow Device Setup screen displays.
d. Press the + or button until Search displays

in the Configure Flow Device field.

e. Press the ENTR button to search for flow

biCoders. The system indicates how many

flow devices it finds.

2. Press the + or button to move through the list

of flow devices, and stop when the serial

number of the flow device that you want to set

up displays in the field.
Note: The system assigns a number from 1 to 4

to each flow device in the order that they are

found. This number is used when programming the flow device or when referring to the flow device from

other menus.

3. Press the NEXT button to move to the Enable field, and then press the + or button to select either Yes or No.

Note: If the flow biCoder is disabled, it will not be used in high flow checking, but it will continue to

accumulate data about the amount of water used.

4. Press the NEXT button to move to the Use Internal NOMV field. If the flow device that you are setting up has

a normally open master valve (NOMV), you can enable it by pressing the +/ buttons. If the flow device does

not have an NOMV, the field displays “na” to indicate that the setting does not apply.

Page

57