Setting Up a Rain Delay

This function will stop all water for a specified number of days. Setting the days to 1 will stop watering for the rest

of the day and will resume normal watering at midnight.

To set up a rain delay

1. Turn the dial to the AUX position.
2. Press the NEXT or PREV button to select Rain/Off, and then press the

ENTR button.

3. Press the + button to set the number of delay days.
4. When you have finished making changes, turn the dial to the Auto Run

position.

To clear a rain delay

1. Turn the dial to the AUX position.
2. Press the NEXT or PREV button to select Rain/Off, and then press the ENTR button.
3. Press the button to change the number of delay days to 0 (zero).

Note: You can also clear a rain delay by viewing the Pause Conditions status from the main screen. Refer to

Pause Conditions on page 78.

4. When you have finished making changes, turn the dial to the Auto Run position.

Setting the System to OFF

Turn the dial to the OFF position when you want to halt all watering for an indefinite period of time. All current

watering cycles will be stopped. No watering cycles will be started. Use this dial position for seasonal shutdown.

DO NOT power down the BaseStation.

When set to OFF, the controller enforces the following conditions:

• It will continue to take biSensor moisture readings every ten minutes

and log them into flash memory.

• It will power down the two-wire (even if it has been set to always be

powered up).

• It will monitor and record flow rate and water usage and will shut

down master valves on high flow, unscheduled flow, or budget

exceeded if they are enabled. Flow readings will be taken at the same

time as moisture readings

Note: The best high flow shutdown is provided with a Flow+NOMV device that is powered externally from a

separate 24 VAC power supply. This device can monitor flow rate 24x7, even with the controller in OFF (or

powered down) and can shut down the NOMV if the high flow limit is exceeded.