Testing all devices – Baseline Systems BaseStation 3200 User Manual

Page 92

Advertising
background image

BaseStation 3200 Advanced Irrigation Controller Manual

page 52)

Ground is too

dry with high

biSensor

moisture

reading

• biSensor not being watered by its primary zone – change the assignment or move

the biSensor to the correct location

• biSensor is buried too deep – rebury the biSensor to be only 3 inches deep

Ground is too

wet with high

biSensor

moisture

reading

• biSensor is buried in low area where water collects – move biSensor from low

area

• biSensor not being watered by its primary zone – change the assignment or move

the biSensor to the correct location

• Program start times are too often – increase the interval between start times
• biSensor limit is too high – lower limit or run a biSensor calibration cycle (refer to

page 52)

Ground is too

wet with low

biSensor

moisture

reading

• biSensor not being watered by its primary zone – change the assignment or move

the biSensor to the correct location

• biSensor is buried too deep – rebury the biSensor to be only 3 inches deep
• Not enough zone water time – increase water time to apply at least ½ inch of

water

Testing All Devices

Before you begin troubleshooting a problem, run a Test ALL from the Self-Test dial position. This test checks all the

devices on the two-wire and displays a summary screen of the results.

If the test finds errors with the devices, the error count is listed for each device type. The quantity of each device

type is also given in parenthesis. This test verifies communication and valve currents, biSensor readings, and other

device readings, but it does not make any repairs.

1. Turn the dial to the Self-Test position.
2. Press the NEXT or PREV button to select Test ALL, and then press the

ENTR button. The test begins. The test results display as illustrated.

3. When the Test ALL is finished, turn the dial to the Auto/Run position.
4. Press the NEXT button to access the messages. The messages attempt

to explain the detected condition and provide some steps that can fix

the most common causes of the condition.

5. When you have finished viewing the test results, return the dial to the

Auto Run position.

As you approach problem solving situations, separate problems into the

following categories:

• It has never worked.
• It worked before and now it does not.

Page

84

Advertising