Technical features – Carlo Gavazzi WM4-96 User Manual

Page 74

Advertising
background image

74

Technical features

Digital outputs

69

Three-phase connections

72

76

83

Sampling: 6400 samples/s @ 50Hz.
Display: graphic back-lighted LCD (128x64 dots).
Selectable read-out for the instantaneous variables: 4x4

digit or 4x3

1

/

2

digit. Total energies: 4x9 digit.

Partials: 4x6 digit.
Max. and min. indication:
Max. 9999 (999999999).
Min. -9999 (–999999999).

Measurements

Curent, voltage, power, energy, power factor, frequency, har-
monic distortion (see display specs). TRMS measurement of
distorted sine waves.
Coupling: direct.
Crest factor:

3, (max. 15Ap/500Vp (“AV5” V L-N),

15Ap/800Vp (“AV7” V L-N).

Input impedance

AV5: 58/100 V (> 500 k

) - 1 AAC (

0.3 VA); 58/100 V

(> 500 k

) - 5 AAC (

0.3 VA); 240 V/415 V (> 500 k

) -1AAC

(

0.3 VA); 240 V/415 V (> 500 k

) - 5 AAC (

0.3 VA).

AV7: 100/170 V (> 500 k

) -1 AAC (

0.3 VA); 100/170 V

(> 500 k

) - 5 AAC (

0.3 VA); 400/690 V (> 500 k

) -1 AAC

(

0.3 VA); 400/690 V (> 500 k

) - 5 AAC (

0.3 VA).

Frequency

40 to 440 Hz.

Overload

Permanent: voltage/current: AV5: 300V

L-N

/ 500V

L-L

/ 6A;

AV7: 480V

L-N

/ 830V

L-L

/ 6A

For 1s: voltage/current: AV5: 600V

L-N

/1040V

L-L

/120A;

AV7: 960V

L-N

/1660V

L-L

/120A

Advertising