Technical features – Carlo Gavazzi WM4-96 User Manual

Page 82

Advertising
background image

82

Technical features

User’s page

77

Software functions

72

84

83

Harmonic analysis

Analysis principle: FFT.

Harmonic measurement: current, up to the 50th harmonic;

voltage, up to the 50th harmonic.

Type of harmonics:

THD (V

L

1) THD odd (V

L

1) THD even (V

L

1).

The same is for the other phases:

L2, L3. THD (A

L

1) THD odd (A

L

1) THD even (A

L

1).

The same is for the other phases: L2, L3.

Harmonic phase angle: the instrument measures the angle

between the single harmonic of “V” and the single harmon-

ic of “I” of the same order. According to the value of the

electrical angle, it is possible to know if the distortion is

absorbed or generated.

Note: if the system has 3 wires the angle cannot be measured.

Harmonic details: the harmonic contents is displayed as a

graph showing the whole harmonic spectrum.

This value is also given as a numerical information:

THD % / RMS value; THD odd % / RMS value; THD odd % /

RMS value / single harmonics in % / RMS value.

System: the harmonic distortion can be measured in single-

phase, 3-wire or 4-wire systems. Tw: 0.02.

Advertising