Series 7 Digital Force Gauges

User’s Guide


20

the desired reading and press DELETE. The letter “D” appears to the left of the record number, indicating
that the gauge is in Delete mode, as follows:


Press ENTER to delete the value. To exit Delete mode, press DELETE again. Any number of readings
may be individually deleted, however, all readings may also be cleared simultaneously. Refer to the Clear
All Data
section for details.

10.2 Statistics
Statistical calculations are performed for the saved values. Calculations include number of readings,
minimum, maximum, mean, and standard deviation.

10.3 Output Data
Press ENTER to output data to an external device. The display will show, “SENDING DATA…”, then
“DATA SENT”. If there was a problem with communication, the display will show, “DATA NOT SENT”.
Saved data can be transmitted to a data collection program such as MESUR

TM

gauge. Refer to their

respective user’s guides for details.

10.4 Output Statistics
Press ENTER to output statistics to an external device. The display will show, “SENDING STATS…”, then
“STATS SENT”. If there was a problem with communication, the display will show, “STATS NOT SENT”.

10.5 Output Data & Stats
Press ENTER to output data and statistics to an external device. The display will show, “SENDING
DATA”, then “SENDING STATS…”, then “DATA SENT”, then “STATS SENT”. If there was a problem with
communication, the display will show, “DATA NOT SENT” and/or “STATS NOT SENT”.

10.6 Clear All Data
Press ENTER to clear all data from the memory. A prompt will be shown, “CLEAR ALL DATA?”. Select
Yes to clear all the data, or No to return to the sub-menu.

Shortcut for clearing all data: In the main menu, highlight Memory and press DELETE. The same
prompt will be shown as above.


For output of data and/or statistics, RS-232 or USB output must be enabled. Data formatting is
<CR><LF> following each value. Units can be either included or excluded. Output of data via the Mitutoyo
output is possible; however, output of statistics is not. Refer to the Communications and Outputs
section for details.

Note:
Data is not retained while the gauge is powered off. However, the gauge protects against
accidental or automatic power-off. If manually powering the instrument off, or if the inactivity time limit for
the Automatic Shutoff function has been reached, the following warning message appears:

0001 2.458 lbF
0002 2.224 lbF
0003 2.446 lbF
0004 1.890 lbF
D

0005 2.098 lbF

0006 1.998 lbF

0007 2.042 lbF