Cooper Instruments & Systems Series M7 Professional Digital Force Gauge User Manual

Page 8

Advertising
background image

Series 7 Digital Force Gauges

User’s Guide


7

4.2 Controls

Primary

Label Primary

Function

Secondary

Label Secondary

Function

Powers the gauge on and off. Press
briefly to power on, press and hold
to power off. Active only when the
home screen is displayed.

ENTER

Various uses, as described in the
following sections.

ZERO

Zeroes the primary reading and
peaks.

(UP)

Navigates up through the menu and
sub-menus .

MENU

Enters the main menu.

ESCAPE

Reverts one step backwards through
the menu hierarchy.

MODE

Toggles between measurement
modes.

(DOWN)

Navigates down through the menu
and sub-menus.

DATA

Stores a value to memory, transmits
the current reading to an external
device, and/or initiates automatic
data output, depending on setup.

DELETE

Enables and disables Delete mode
while viewing stored data / shifts
cursor to the right for certain
functions.

UNITS

Toggles between measurement
units.

DIRECTION Reverses the display during

calibration, and toggles between
tension and compression directions
while configuring set points and other
menu items.

Turns the LCD backlight on and off.

N/A

N/A


4.3 Menu navigation basics
Most of the gauge’s various functions and parameters are configured through the main menu. To access
the menu press MENU. Use the

and

keys to scroll through the items. The current selection is

denoted with clear text over a dark background. Press ENTER to select a menu item, then use

and

again to scroll through the sub-menus. Press ENTER again to select the sub-menu item.


For parameters that may be either selected or deselected, press ENTER to toggle between selecting and
deselecting. An asterisk (*) to the left of the parameter label is used to indicate when the parameter has
been selected.

For parameters requiring the input of a numerical value, use the

and

keys to increment or

decrement the value. Press and hold either key to auto-increment at a gradually increasing rate. When
the desired value has been reached, press ENTER to save the change and revert back to the sub-menu
item, or press ESCAPE to revert back to the sub-menu item without saving. Press ESCAPE to revert one
step back in the menu hierarchy until back into normal operating mode.

Refer to the following sections for details about setting up particular functions and parameters.



5 DIGITAL FILTERS


Digital filters are provided to help smooth out the readings in situations where there is mechanical
interference in the work area or test sample. These filters utilize the moving average technique in which
consecutive readings are pushed through a buffer and the displayed reading is the average of the buffer
contents. By varying the length of the buffer, a variable smoothing effect can be achieved. The selection
of 1 will disable the filter since the average of a single value is the value itself.

To access digital filter settings, select Filters from the menu. The display appears as follows: