Canon SX20 User Manual

Page 78

Advertising
background image

78

MAINTENANCE

Procedure for Replacing the Lamp

Turn off the projector and disconnect
the power plug from the AC outlet.
Allow the projector to cool for a least
1 hour.

Detach the lamp cover by loosening
a screw with a flathead screwdriver.

Loosen two screws, turn up the
handle, and remove the lamp.

Insert a new lamp as far as it will go
and secure it with two screws.
* After installation, be sure to turn

down the handle.

Install the lamp cover and tighten the
screw.

Turn on the projector.

Bring up the menu and select
[System settings] -> [Lamp counter].
(P74)

Select [Reset] -> [OK] to reset the
lamp counter.

Lamp

Screws

Handle

1

2

Screw

Lamp cover

Lamp cover

8

7

6

5

3

4

Advertising