4.2.1 Code (steps)
Click Code (steps) to set the type of code for the singleturn range (steps / revolution). Possible
settings are e.g. Binary, Clamped Gray, Gray or BCD Code.

4.2.2 Code (Revolutions)
Click Code (revolutions) to set the type of code for the multiturn range (revolutions). Possible
settings are e.g. Binary, Gray or BCD Code.

4.2.3 Code format
Click Code format to determine the output format. In case of a closed code, the initial value is
displayed as a consecutive value. In case of a separated code, the initial value is separated
according to steps / revolution and revolutions.

Example:

In case of a setting of 10 steps / revolution and 16 revolutions
Separated code:

Steps

0, 1, 2, 3....8, 9

→ 0, 1, 2.....

Revolutions

0....................0

→ 1, 1........

Steps

Revolution

0....9 0
0....9 1
0....9 2
0....9 3

... ...


Closed

code:

Entire

resolution: 0, 1, 2, 3...8, 9,......150, 151,...158, 159

Р

Р

revolution 1

revolution 16

Advertising