4.4.1 Output format
The output format offers the choice between „left-justified“ and „tree“. In case of the „left-
justified“ data format, the data is output starting with the revolutions. After the revolutions,
zeros are sent up to the pulse space.
In case of the „tree“ the position values is always 25 bit. If the position value is smaller, the
other digits will be padded with zeros.

Example for output format “tree” and „left-justified with zeros“:

Number of turns

Position value

Steps within on turn

4095 111111111111/1111111111111

8191

511 000111111111/1111111111000

1023

127 000001111111/1111111000000

255

7 000000000111/1111000000000

15

1 000000000001/1100000000000

3



Example for output format „left-justified“:

Number of turns

Position value

Steps within on turn

4095 111111111111/1111111111111

8191

511 111111111/1111111111000000

1023

127 1111111/111111100000000000

255

7 111/1111000000000000000000

15

1 1/110000000000000000000000

3