4.8 Explanation cam switching mechanism

The programmable cam switching mechanism allows the execution of switching processes.
In this case, altogether 250 cams can be programmed to 16 outputs (e.g. GN400 or GXN1W).
A maximum number of 250 cams can be assigned to each of the 16 outputs.
Furthermore you can determine after how many steps and revolutions of the encoder shaft a
cam is to trigger a switching process (on/off).

The input fields „ON steps“ and „OFF steps“ are for input of the number of turns to be realized
by the cam unit after being switched on resp. off. The input fields „ON steps“ and „OFF steps“
are for input of the number of steps to be realized by the cam unit after bing switched on resp.
off.

A message gives information on the maximum possible value for both numbers of turns and
steps.

After the selection of the register card „cam“ the following window will be displayed: