Baumer G1-G2-GB-GXxxx User Manual

Page 23

Advertising
background image

Manual_ProGeber_V1-40_EN.doc 23/40

Baumer IVO GmbH & Co. KG

10.05.11

Villingen-Schwenningen,

Germany

4.3.1 Special outputs
The special outputs available are marked in red. Their number is depending on the total
resolution selected as well as the code format. The outputs D19 to D23 allow a maximum
assignment of 5 special outputs.

The outputs may be assigned in optional way to one of the following 6 functions, whilst the
corresponding function selected can be assigned exclusively to one output.
• Preset 1: Output switches when the set value is exceeded.
• Preset 2: Output switches when the set value is exceeded.
• Speed monitoring: Output switches when the actual value falls below the set value. The

value input in turns/minute.

• Battery control: Output triggers as soon as the voltage value for the lithium cell is falling

below the critical point. However, the encoder function still remains secure for another three
months.

• DataValid: Output switches when the checking of the code is faulty.
• DataValid + battery control: Both functions are assigned to the same output as a collective

message


Open-circuited and closed-circuited can be changed via the function "output logic"
(see chapter 4.4.6 Output logic).

4.3.2 Least significant bit (LSB) revolutions
The input field „least significant bit turns“ only appears if the resolution of steps/turn is inferior
to the maximum resolution of 12 Bit thus indicating existing outputs not assigned. If so, the
position of the turns within the range of D8 to D12 can be shifted to the position of output D8.

4.3.3 Domain „special outputs“
The domain „special outputs“ is used to select the desired position or rpm at which the special
outputs are to switch. The domain can be displayed by moving the mouse to the input field.