5 wiring the encoders, 1 wiring between pc and encoder – Baumer G1-G2-GB-GXxxx User Manual

Page 35

Advertising
background image

Manual_ProGeber_V1-40_EN.doc 35/40

Baumer IVO GmbH & Co. KG

10.05.11

Villingen-Schwenningen,

Germany

5 Wiring the encoders

5.1 Wiring between PC and encoder


In order to facilitate the connection between the PC and the encoder, the encoder is equipped
with a RS232 interface. In addition, the encoder can be directly connected to the PC. For any
transmission distance of more than 30 m RS485 interface is recommended.

5.1.1 Contact parallel encoder
In order to program the parallel encoders with the PC, the lines TxD, RxD and GND must be
connected.

Contact assignment for shaft encoder:

Shaft encoder
function

M12 connector,
5-pin

PC contact
D-SUB, 9-pin

- Pin

1

-

RxD

Pin 2

Pin 3

GND

Pin 3

Pin 5

TxD

Pin 5

Pin 2

Br. Pin 4 to 6

Br. Pin 7 to 8


Also connect the encoder via the device plug to voltage (UB/red/Pin 36 and GND/blue/Pin 37).

Accessories: Z 139.005

Programming cable for parallel shaft encoder

Programming software ProGeber

Manual on CD

Advertising