Room solutions, Crestron commercial lighting design guide 41, Mode val ue sa ve cancel – Crestron electronic Green Light GLPS-HSW-FT User Manual

Page 45: Example glpac-dimflv application

Advertising
background image

Crestron Commercial Lighting Design Guide

41

Room Solutions

Flexibility
Each GLPAC can be used to control a single room, or up to four independent rooms. Single-room control is available right out of the box,
with no additional configuration. Multi-room control and other system adjustments are accomplished using local controls on the GLPAC
or via the built-in web interface. And because the GLPAC is a Crestron 2-Series control processor, limitless customization is possible for
specialized applications.

Save Energy
Enjoy a greener conscience with the GLPAC. Built-in support for occupancy sensing and daylight harvesting help control spending while
saving energy. Automatically turn off lights in unoccupied areas and maintain balanced bulb brightness with the natural light level in the
room. Crestron GLS sensors can be placed strategically in each space to maximize the benefits of energy management.

Built-in Power Monitoring (-PM models only)
Optional power monitoring tracks the real time energy usage of each load, thereby delivering statistics to help control energy costs. By
analyzing real data, organizations can make more educated decisions regarding energy resources, which will have greater impact on
the bottom line.

Easy Deployment

Packaged in one metal enclosure, the GLPAC can be deployed in small spaces, including plenum ceilings. The surface-mount GLPAC
can be affixed to a wall or ceiling rafter, cleanly out of sight. Standard wire-entry knockouts are provided.

Example GLPAC-DIMFLV Application

GLPAC-DIMFLV Products

GLPAC-DIMFLV4

4 Dimmer Channels

GLPAC-DIMFLV4-PM

4 Dimmer Channels with power monitoring and four 1A rated relays

GLPAC-DIMFLV8

8 Dimmer Channels

GLPAC-DIMFLV8-PM

8 Dimmer Channels with power monitoring and four 1A rated relays

®

MODE

VAL

UE

SA

VE

CANCEL

8 8

8 8

NEUT

LINE1

SW1

LINE2

SW2

LINE3

SW3

LINE4

SW4

CAUTION!

RISK O

F ELECTRICA

L S

HOC

K -

More t

han one circu

it breaker

required to de-en

ergize unit.

+

-

+

-

+ -

+

-

+ -

+ -

+ -

+ -

1

2

3

4

5

6

7

8

1

0-10VDC

(CLASS 1 OR CLASS

2 WIRING)

60m

A MAX/OUT

PUT

, SINK O

ML

Y

PWR

NET

-L

MSG

HW

-R

SW

-R

OVR

NET

-C

LAN

USB

INPUT

: 100 - 277

VA

C 50/60 Hz

MAXIMUM LOAD:

16A

PER CIRCUIT

DIMMED LOAD TYPES:
0-10 VDC FLUORESCENT BALLAST
SWITCHED LOAD T

YPES

:

INCANDESCENT

, M

LV

, E

LV

, NEON/CC

FLUORESCENT BALLAST

, HID

GL

PAC-DIMFL

V4

Multi-Room Lighting Controller with Power Management

UL

C

US LI

STED

IND.

CONT

. EQ

.

48DO

CONT

SYS

NET

OVE

RRIDE

LOC

AL

NET

SIGNA

L REL

AYS

CON

TAC

T C

LOSURES

OCC

SENSORS

PHO

TOC

ELL

S

PHOTOCELL

SENSOR

OCCUPANCY

SENSOR

LOW

VOLTAGE

SWITCHES

PC

VAV

MASTER

CONTROL

PROCESSOR

ELECTRIC

UTILITY

LIGHTING

LIGHTING

LIGHTING

LIGHTING

LAN

SHADES

CONTACT

CLOSURE

KEYPADS

S

T

LIGHTS

LIGH

TS

TEMP

VOLUME

VOLUME

TEMP

S

T

S

T

Color Key

Control
Sensors

AC
Cresnet

LAN

Advertising