Additional Information

Remote Control Function Using

a Parallel Remote Connector

You can operate the deck with a parallel remote control
that uses a switch box connected to the REMOTE 1
connector on the rear panel.

Using the REMOTE 1 connector

When operating the deck with a parallel remote
control, set the REMOTE switch on the front panel to
WIRED.
The pin numbers and pin assignments for the

REMOTE 1 connector on the rear panel are as follows:

DIN connector (8 pin)

Case

Pin No

M0DE1

(playback)

M0DE2
(recording)

Inputs

1

H-level constant

L-level constant

2 ■

H-BTOP/L-PLAY

L-STOP

3

L-STOP

L-START ID
WRITE

4

L-PLAY

L-PLAY

5

L-REW

L-PAUSE

6

L-FF

L-REC

Status

7

H-STOP

H-REC-PAUSE

output

8

H-PLAY

H-REC

Case

GND

GND

Command inputs H: OPEN (off impedance: 30 kilohms or

more)

L: GND short (on impedance: 100 ohms

or less)

Status output H: approx 2V (I=15mA)

L: OPEN (High impedance)

Connection diagram (MODE 1)

1

2

3

4

5

6

7

8 Case

ci| c!)| (!)| (i| 1)|

OPEN

,GND

Notes

• When using MODE 2, use pin number 1 for GND.
• By keeping the input to pin number 1 constant at either H-

level or L-level determines whether pin numbers 2 to 8 are
in MODE 1 (playback) or MODE 2 (recording).

• In MODE 1, pin number 2 may be used for fader-start

function.

• For pin numbers 2 to 6 pin, input to smaller numbers take

priority.

• Anti-chattering measures should be taken for the

command input switches.

• Status output (pin numbers 7 and 8) is specially provided

for driving a single LED. If more current is needed, use an
additional drive circuit or electric power supply.

• Do not switch input to pin number 1 (MODE 1 and MODE

2) while the deck is playing or recording. This may result
in mis-operation of the deck.

Disabling Button Operations
(Key Protect Function)

(PCM-R700 Only)

You can disable certain button operations so that the
buttons do not work during, for instance, recording.

KEY PROTECT

AM of these buttons and dials

are disabled.

Set KEY PROTECT to ON.

Command input Status output

switch

display (LED)

2 8 ^