Serial port connector: com1 / com2, Rs-422 / rs-485 specifications, Caution – Contec SEH-9450-LAS User Manual

Page 21

Advertising
background image

3. Hardware Installations

14

SEH-9450-LAS

Serial Port Connector: COM1 / COM2

Serial 1 (COM1), Serial 2 (COM2), are onboard serial ports of the product. The following table shows
the pin assignments of these connectors.

Table 3.4.

Serial Port Connector

PIN No.

RS-232C

RS-422

RS-485

1 DCD TX- TX-
2 RXD TX+ TX+
3 TXD RX+ RX+
4 DTR RX- RX-
5 GND GND GND
6 DSR N.C. N.C.
7 RTS N.C. N.C.
8 CTS N.C.

N.C.

9 RI N.C.

N.C.

COM1 / COM2

1

6

5

9

10 N.C. N.C. N.C.

CAUTION

-

For RS-485, TX+(pin 2) and RX+ (pin 3) must jumper together inside the D type connector.

-

TX- (pin 1) and RX- (pin 4) is the same.

RS-422 / RS-485 specifications

-

Transmission system: Asynchronous, half-/full-duplex serial transmission conforming to
RS-422/RS-485

-

Baud rate : 115,200 - 50bps (programmable)

-

Signal extensible distance: 1.2km Max.

RTS#

R

D

1ΚΩ

JCOM1: 14-6

JCOM1: 15-6

SOUTB

6.2ΚΩ

6.2ΚΩ

4.7KΩ

4.7KΩ 4.7KΩ

4.7KΩ 4.7KΩ

4.7KΩ

10 5

6 1

Figure 3.1.

RS-422 / RS-485

Advertising