Cf master / slave selector: jp1, Rs-232/422/485 selector: jcom1 – Contec SEH-9450-LAS User Manual

Page 33

Advertising
background image

4. Jumper Setting

26

SEH-9450-LAS

CF Master / Slave selector: JP1

On board CF slot is connected to Secondary IDE. This jumper is select Master/Slave of CF memory
card. Usually, please use it with a master setup.

Table 4.3.

CF Master / Slave selector

JP1

Function

1
2
3

Set to Master

1
2
3

Set to Slave (Default)

RS-232/422/485 Selector: JCOM1

Table 4.4.

RS-232/422/485 Selector

RS-232C

(Default)

JCOM1

19 17 15 13 11 9 7 5 3 1

20 18 16 14 1210 8 6 4 2

RS-422

JCOM1

19 17 15 13 11 9 7 5 3 1

20 18 16 14 1210 8 6 4 2

RS-485

JCOM1

19 17 15 13 11 9 7 5 3 1

20 18 16 14 1210 8 6 4 2

1.

For RS-485, TX+ (pin2) and RX+ (pin3) must jumper together inside the D type connector.

2.

TX- (pin1) and RX- (pin 4) is the same.

Transmit date control in half-duplex mode

In half-duplex mode, the transmission buffer must be controlled to prevent transmit data from causing a
collision. The SEH-9450-LAS uses the RTS signal and bit 1 in the modem control register to control
transmit data.

Modem control register

(Setting I/O address +4H) bit 1:

0 … RTS High (Disables transmission)

1

RTS

low

(Enables

transmission)

Advertising