27

OFF = Will prevent rotation from occurring.

CONT = Runs the travel at the PRIMARY-RPM speed only, regardless of PULSE

MODE.

STEP = Will pulse the travel between the PRIMARY-RPM and BACKGROUND-RPM

speed. If the TRAVEL MODE is in STEP but the PULSE MODE is in OFF then only

PRIMARY will occur (without pulsing there are no background functions).

8.

LEVEL 1 PRIMARY-RPM - After the Travel Start Delay time is complete the travel

function will begin. If the Level 1 Travel Mode is programmed to CONT the travel will be

rotating the arc at the Primary-RPM rate continuously regardless of any pulsing. If the

Travel Mode is STEP it will rotate the arc at the Primary-RPM speed each time the

system goes to PRIMARY.

9. LEVEL 1 BACKGROUND RPM - If the LEVEL 1 PULSE MODE is in ON or SYNC and

the TRAVEL MODE is in STEP the system will rotate the arc at the BACKGROUND-

RPM each time the system goes to a BACKGROUND pulse.

NOTE

Travel direction is programmable CLOCKWISE or COUNTER- CLOCKWISE. After the

Travel Start Delay the Head will rotate in the programmed direction. The direction is not

programmable

by

LEVELS.

10. LEVEL 1 PRIMARY WIRE - After the Wire Start Delay time is complete the Wire

Feeder will feed at the Primary Wire Feed value whenever the system is in Primary and

the Wire Mode is set to ON.

11. LEVEL 1 BACKGROUND WIRE - After the Wire Start Delay is complete the Wire

Feeder will feed at the Background Wire Feed value whenever the system is in

Background and the Wire Mode is ON.

12. LEVEL 1 AVC MODE - The AVC can be set in each Level to work

several

different

ways:

OFF = Will prevent the AVC servo from operating.

CONT = Allows the AVC to work continuously both in the PRIMARY and

BACKGROUND functions, using the Level 1 AVC value when in Primary and using the

Level 1 Background AVC value when in Background.

SAMP/PRI = Allows the AVC to work only during the PRIMARY current, using only the

Primary AVC value. The AVC position will not move during Background.

SAMP/BCK = Allows the AVC to work only during the BACKGROUND current, using

only the Background AVC value. The AVC position will not move during Primary.

13. LEVEL 1 PRIMARY AVC - After the AVC START DELAY time is complete and the AVC

MODE is in CONT or SAMP/PRI. the AVC will maintain this value during the Primary

current.

14. LEVEL 1 BACKGROUND AVC - After the AVC START DELAY time is complete and

the AVC MODE is in CONT or SAMP/BCK the AVC will maintain this value during the

Background

current.

15. LEVEL 1 OSCILLATOR AMPLITUDE - Is the distance the Torch

Oscillator will move from full IN to full OUT during the EXCURSION

TIME programmed in LEVEL 1.

16. LEVEL 1 OSCILLATOR EXCURSION TIME - The time in LEVEL

1 that the oscillator will travel from full IN to full OUT position.

Advertising