2. To manually calibrate the user will need to have a Weld Schedule in the Library programmed

in accordance to the Calibration Procedure contained in the operation manual for the

particular Weld Head being used.


5.9

WELD HEAD TRAVEL CALIBRATION

3.

A Travel calibration schedule will always be run in TEST Mode and usually

contains the following:


Onelevel Functions

Prepurge

000

Level Advance

Time 1.0

Upslope

00.0

Start Mode

RF

Wirefeed Start Delay 00.0

WF Retract

0.0

Travel Start Delay 00.0

Travel Direction

CCW

Postpurge

000

Downslope

00.0

Wirefeed Stop Delay

00

Travel Stop Delay

00

Multilevel Functions (Level 1)

Level Time

***

Pri Amps

005

Pulse Mode

OFF

Pri Wirefeed

000

Pri Travel

***

Travel Step

CONT

Multilevel Functions (Level 2) For weld Heads with the return to home function Only!

Level Time

005

Pri Amps

005

Pulse Mode

OFF

Pri Wirefeed

000

Pri Travel

0.0

Travel Step

OFF

INSURE THAT THE WELD/TEST MODE IS IN TEST

4. ***Level 1 Time needs to be set for rotating weld heads (programmed in RPM) the time to

rotate ONE REVOLUTION at the selected LEVEL 1 Primary Travel Speed. For weld heads
programmed in IPM (such as a Model 15), the Level 1 Time needs to be set to give a
measurable travel distance in inches or millimeters. It is suggested to check calibration at a
speed close to typical welding speeds being used and adjust the Level 1 time accordingly.

Level 2 is added with Travel turned OFF. This allows the operator time to see if the distance

traveled is correct before the “Return to Home” function engages at the end of the

Sequence (on some heads). LEVEL 2 CAN BE OMITTED FOR WELD HEADS THAT

DO NOT HAVE A RETURN HOME FUNCTION .

5. Create or recall from the LIBRARY the appropriate Weld Schedule and connect the Weld

Head to be calibrated. Insure that the system is SAFE to rotate and that the System Mode is

in TEST. Note the starting position of the Weld Head and Press Sequence Start. At the end

of the Sequence the weld head should have rotated or traveled the programmed amount.


6. If it has not rotated or moved the correct distance then adjust the Weld Head Rotation/

Travel Calibration Potentiometer.


7.

Repeat 5 and 6 until the head is calibrated.