2-12

Functional Description and Specifications

Data Storage/Recall w/Date Time Stamp

3,000 measurements

Statistical Analysis

Max, Min, Range, Mean, Sigma N, Sigma, Cp, Cpk

%Error, -NoGo, +NoGo.
Histogram: Lower Set Limit, Upper Set Limit, 10 Divisions

Printer/Computer Serial Output Port

Serial Communications

RS-232 (true)

300—19.2K Baud
8 data bits

1 stop bit

no parity

Computer Serial COM Port

RS-232 (True)
300—19.2K Baud

NOTE

OPTIONAL: This port will communicate with the Motorized
Control Box at 19.2K Baud.

Analog Output

+(CW)/-(CCW) 1.8V at transducer full range linearity
±1% of reading

Loader Control Relays

Two, normally open, Form A, rated 12VDC @ 1/2A close
contact at 110% CW or CCW of torque/force transducer range.

For additional information refer to Transducer and

System specifications.

Display Capacity

(16 bit A/D), 8 digits, ±32,000 counts

Units of Measurement

Torque
ft lb, in lb, in oz, Nm, dNm, cNm, mkg and cmkg

Force
lbf, ozf, N, dN, kp, and gf

Angle
degrees

Torque/Force Resolution

Refer to transducer-indicator range and display resolution tables
in Functional Description of this chapter.

Angle Resolution

Bi-directional, X4 quadrature logic