Step 8) heavy-duty anchor installation, Includes offset and center-set glazing), Offset mullions center-set mullions – EFCO 433 Series User Manual

Page 55: Series 433 triple set installation instructions

Advertising
background image

June 2012

PART NO. Y017

Page 55 of 90

Series 433 Triple Set Installation Instructions

SECTION VI: Subsill Fabrication and Installation

(Includes Offset and Center-Set Glazing)























Step 8) Heavy-Duty Anchor Installation

Install required vertical mullion
anchors as shown in Figures 14

through 18. Anchors should be
installed on the vertical mullions and

anchored thru the subsill after the
frame unit is installed in the

opening. HD anchors will not work
with 8349 or 8357 mullions.

5/16"

27/64"

3/16"

51/64"

23/64"

7/8"

29/64"

21/64"

27/64"

7/16"

K992

K992

K473

K473

SUBSILL

2S44

INSIDE SET GLASS

OUTSIDE SET GLASS

CENTER-SET GLASS

[FIG. 16]

[FIG. 18]

NOTE: K992 COMES WITH TWO ANGLE

BRACKETS AND TWO FASTENERS. K473

COMES WITH ONE ANGLE BRACKET AND

TWO FASTENERS.

1 1/8" ± 1/16"

1 1/8" ± 1/16"

7/8"

OFFSET MULLIONS

CENTER-SET MULLIONS

1 5/16"

3 5/8"

[FIG. 15]

[FIG. 14]

[FIG. 17]

1 1/8" ± 1/16"

3 5/16"

SUBSILL

2S44

SUBSILL

2S44

K473

K992

Do not use 4471 Subsill
with heavy duty anchors.

These recommendations are for general erection procedures only. For actual job

conditions, see the details on the shop drawings. For perimeter anchor type and
spacing, refer to the approved shop drawings or consult the project design professional.

Advertising