Step 4) installing glass blocks, Fig. 98] [fig. 99, Includes offset and center-set glazing) – EFCO 433 Series User Manual

Page 78

Advertising
background image

June 2012

PART NO. Y017

Page 78 of 90

Series 433 Triple Set Installation Instructions

SECTION IX: Glazing

(Includes Offset and Center-Set Glazing)























Step 4) Installing Glass Blocks

HN32

HN92

OUTSIDE SET, INSIDE GLAZED

SHOWN. OTHERS ARE SIMILAR

TYP. SILL

TYP. HORIZ.

[FIG. 98]

[FIG. 99]

D.L.O. / 4

D.L.O. / 4

D.L.O. / 8

D.L.O. / 8

1/4 POINT

BLOCKING

1/8 POINT

BLOCKING

4 ½” SILLS &

HORIZONTALS

SIMILAR

[FIG. 99]

[FIG. 100]

Glass blocks for the 433 system are designed to be used at 1/4 points and 1/8 points

for special dead load applications. For intermediate horizontals, use glass block HN92.
For sills, use glass block HN32. It may be necessary to use a small amount of sealant

on the bottom of the glass blocks to ensure they remain in the intended position. Refer
to Figure 100 below for 1/4 point and 1/8 point verification.

Advertising