INCLUDES CAPTURED AND STRUCTURAL GLAZED MULLION SYSTEMS

STEP 4) INSTALLING THE S.S.G. MULLION HORIZONTAL

BRIDGE ASSEMBLY

MDM

01/2007

Press the bridge assembly into

the sealant and apply a bead of

sealant to the perimeter seam of

the bridge. Tool into the

horizontal and vertical to achieve

a water seal at the bridge.

Apply silicone type sealant to the

ends of horizontals and across
S.S.G. mullion before installing
the bridge assembly.

Tool sealant smooth and

flat, as not to interfere with

glazing.

[FIG. 53]

[FIG. 54]

STEP 5) SEALING THE INTERIOR GASKET FOR OUTSIDE

GLAZING

PAGE 40

8341

8341

8308

8309

K483

SECTION IX - GLAZING (cont.)

NOTE: USE THIS PROCEDURE

WHERE THE STRUCTURAL GLAZED

EXPANSION MULLION IS USED.

Before installation of the glass units, seal 1" of the interior gasket horizontally and vertically at

all intersections. Pull the WNE0 out of the race at the intersection, seal with a silicone type
sealant, and reinstall in the gasket race. After reinstalling the gasket, seal the ends of all
gaskets. See Figure 65 on page 43.