3 fat pipe interconnect, 4 storage interconnect, 3 fat pipe interconnect 3.1.4 storage interconnect – Kontron AT8404 User Manual

Page 36

Advertising
background image

Hardware Description

23

AT8404 User Guide

www.kontron.com

3.1.3 Fat Pipe Interconnect

AMC bays B1 and B2 as well as B3 and B4 are directly (copper) interconnected via AMC Fat Pipe ports 4-7, see
following table.

3.1.4 Storage Interconnect

A port selector is used to configure either a storage connection between the AMC B2 and B4 or B1 and B4. The
port selector is controlled by the IPMC.

Depending on the configuration, the SAS/SATA ports of the four mid-size AMC bays are interconnected as fol-
lows:

For more information on how to configure the AMC Storage connections, refer to the AT8404 CLI Reference
Manual.

Table 3-5:

Fat Pipe Interconnect

AMC Port

Connects to

B1 port 4

B2 port 4

B1 port 5

B2 port 5

B1 port 6

B2 port 6

B1 port 7

B2 port 7

B2 port 4

B1 port 4

B2 port 5

B1 port 5

B2 port 6

B1 port 6

B2 port 7

B1 port 7

B3 port 4

B4 port 4

B3 port 5

B4 port 5

B3 port 6

B4 port 6

B3 port 7

B4 port 7

B4 port 4

B3 port 4

B4 port 5

B3 port 5

B4 port 6

B3 port 6

B4 port 7

B3 port 7

Table 3-6:

AMC Storage Interconnect

AMC Port

Connects to

B1 port 2

B3 port 2

B1 port 3

B4 port 2 via port selector

B2 port 2

B4 port 2 via port selector

B2 port 3

RTM port SAS_0

B3 port 2

B1 port 2

B3 port 3

-

B4 port 2

B1 port 3 or B2 port 2 via port selector

B4 port 3

RTM port SAS_1

Advertising