Kontron AT8404 User Manual

Page 70

Advertising
background image

Software Description

57

AT8404 User Guide

www.kontron.com

18

FRU2 Hot
Swap

0xF0
(PICMG Hot
Swap)

0x6F
(Sensor Spe-
cific)

PICMG hotswap sensor
for AMC B2

see PICMG 3.0R2.0 section
3.2.4.3 for event trigger and
sensor definition

19

FRU3 Hot
Swap

0xF0
(PICMG Hot
Swap)

0x6F
(Sensor Spe-
cific)

PICMG hotswap sensor
for AMC B3

see PICMG 3.0R2.0 section
3.2.4.3 for event trigger and
sensor definition

20

FRU4 Hot
Swap

0xF0
(PICMG Hot
Swap)

0x6F
(Sensor Spe-
cific)

PICMG hotswap sensor
for AMC B4

see PICMG 3.0R2.0 section
3.2.4.3 for event trigger and
sensor definition

21

FRU5 Hot
Swap

0xF0
(PICMG Hot
Swap)

0x6F
(Sensor Spe-
cific)

PICMG hotswap sensor
for the RTM

see PICMG 3.0R2.0 section
3.2.4.3 for event trigger and
sensor definition

22

IPMB0 Link
State

0xF1
(PICMG Physical
IPMB-0)

0x6F
(Sensor Spe-
cific)

PICMG IPMB0 link state

see PICMG 3.0R2.0 section
3.8.4.2 for event trigger and
sensor definition

23

FRU0 IPMBL
State

0xC3 OEM
(IPMB-L link
state)

0x6F
(Sensor Spe-
cific)

IPMB-L link state to
FRU0

offset 2 and 3 are used
for details see 4.3.1.1 OEM
sensor description

24

FRU1 IPMBL
State

0xC3 OEM
(IPMB-L link
state)

0x6F
(Sensor Spe-
cific)

IPMB-L link state to
AMC B1

offset 2 and 3 are used
for details see 4.3.1.1 OEM
sensor description

25

FRU2 IPMBL
State

0xC3 OEM
( IPMB-L link
state)

0x6F
(Sensor Spe-
cific)

IPMB-L link state to
AMC B2

offset 2 and 3 are used
for details see 4.3.1.1 OEM
sensor description

26

FRU3 IPMBL
State

0xC3 OEM
( IPMB-L link
state)

0x6F
(Sensor Spe-
cific)

IPMB-L link state to
AMC B3

offset 2 and 3 are used
for details see 4.3.1.1 OEM
sensor description

27

FRU4 IPMBL
State

0xC3 OEM
( IPMB-L link
state)

0x6F
(Sensor Spe-
cific)

IPMB-L link state to
AMC B4

offset 2 and 3 are used
for details see 4.3.1.1 OEM
sensor description

28

FRU5 IPMBL
State

0xC3
(IPMB-L link
state)

0x6F
(Sensor Spe-
cific)

IPMB-L link state to the
RTM

offset 2 and 3 are used
for details see 4.3.1.1 OEM
sensor description

29

FRU0 FRU
Agent

0xC5
(FRU Info Agent)

0x6F
(Sensor Spe-
cific)

Generates an event
when the FRU data of
this devices is parsed

offset 6,8 are used
for details see 4.3.1.1 OEM
sensor description

30

FRU1 FRU
Agent

0xC5
(FRU Info Agent)

0x6F
(Sensor Spe-
cific)

Generates an event
when the FRU data of
this devices is parsed

offset 6,8 are used
for details see 4.3.1.1 OEM
sensor description

31

FRU2 FRU
Agent

0xC5
(FRU Info Agent)

0x6F
(Sensor Spe-
cific)

Generates an event
when the FRU data of
this devices is parsed

offset 6,8 are used
for details see 4.3.1.1 OEM
sensor description

32

FRU3 FRU
Agent

0xC5
(FRU Info Agent)

0x6F
(Sensor Spe-
cific)

Generates an event
when the FRU data of
this devices is parsed

offset 6,8 are used
for details see 4.3.1.1 OEM
sensor description

Table 4-4:

AT8404 sensors (Continued)

SDR

ID

Name

Sensor Type

Code

Reading Type

Code

Description

Event Offset

Advertising