Table 4-6: kontron ipmb-l link sensor – Kontron AT8404 User Manual
Page 76
Software Description
63
AT8404 User Guide
www.kontron.com
Kontron IPMB-L Link
Table 4-6:
Kontron IPMB-L Link sensor
Event/Reading
type code
Sensor type
Sensor specific
offset
Event trigger
0x6F
0xC3
OEM Kontron
IPMB-L Link
0x02
IPMB-L Disable
Event Data 2: always 0
Event Data 3:
bit[7:3]: always 0
bit [2:0]:
0h = no failure
1h = Unable to drive clock HI
2h = Unable to drive data HI
3h = Unable to drive clock LO
4h = Unable to drive data LO
5h = clock low timeout
6h = Under test (the IPM Controller is attempting
to determine who is causing a bus hang)
07h = Undiagnosed Communication Failure
0x03
IPMB-L Enable
Event Data 2: always 0
Event Data 3:
bit[7:3]: always 0
bit [2:0]:
0h = no failure
1h = Unable to drive clock HI
2h = Unable to drive data HI
3h = Unable to drive clock LO
4h = Unable to drive data LO
5h = clock low timeout
6h = Under test (the IPM Controller is attempting
to determine who is causing a bus hang)
07h = Undiagnosed Communication Failure