12 cmdgetstorageportselection, 13 cmdsetstorageportselection – Kontron AT8404 User Manual

Page 92

Advertising
background image

Software Description

79

AT8404 User Guide

www.kontron.com

4.3.2.12

CmdGetStoragePortSelection

This command reads the current setting of the storage switch between AMC B4 and AMC B1/AMC B3.

4.3.2.13

CmdSetStoragePortSelection

Command Name

NetFn

LUN

Command Number

CmdGetStoragePortSelection

0x30

3

0x91

Byte Num

Data Field

Request Data

1...5

Token:
0xAB - (~T)
0xCA - (~5)
0xCC - (~3)
0xCF - (~0)
0xC8 - (~7)

6

Device:
0 – switch located at AMC B4

Response Data

1

Completion Code

2

Setting:
0 - the AMC B4 (port 2) is connected to AMC B1 (port 3)
1 - the AMC B4 (port 2) is connected to AMC B2 (port 2)

Command Name

NetFn

LUN

Command Number

CmdSetStoragePortSelection

0x30

3

0x92

Byte Num

Data Field

Request Data

1...5

Token:
0xAB - (~T)
0xCA - (~5)
0xCC - (~3)
0xCF - (~0)
0xC8 - (~7)

6

Device:
0 - switch located at AMC B4

7

Setting:
0 - the AMC B4 (port 2) is connected to AMC B1 (port 3)
1 - the AMC B4 (port 2) is connected to AMC B2 (port 2)

Response Data

1

Completion Code

Advertising